Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. bras. cir. cardiovasc ; 38(6): e20230045, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1507837

RESUMO

ABSTRACT This short article discusses selected scanning electron microscope and transmission electron microscope features of vasa vasorum including pericytes and basement membrane of the human saphenous vein (SV) harvested with either conventional (CON) or no-touch (NT) technique for coronary artery bypass grafting. Scanning electron microscope data shows the general damage to vasa vasorum of CON-SV, while the transmission electron microscope data presents ultrastructural features of the vasa in more detail. Hence there are some features suggesting pericyte involvement in the contraction of vasa blood vessels, particularly in CON-SV. Other features associated with the vasa vasorum of both CON-SV and NT-SV preparations include thickened and/or multiplied layers of the basement membrane. In some cases, multiple layers of basement membrane embrace both pericyte and vasa microvessel making an impression of a "unit" made by basement membrane-pericyte-endothelium/microvessel. It can be speculated that this structural arrangement has an effect on the contractile and/or relaxing properties of the vessels involved. Endothelial colocalization of immunoreactive inducible nitric oxide synthase and endothelin-1 can be observed (with laser confocal microscope) in some of the vasa microvessels. It can be speculated that this phenomenon, particularly of the expression of inducible nitric oxide synthase, might be related to structurally changed vasa vessels, e.g., with expanded basement membrane. Fine physiological relationships between vasa vasorum endothelium, basement membrane, pericyte, and perivascular nerves have yet to be uncovered in the detail needed for better understanding of the cells'specific effects in SV preparations for coronary artery bypass grafting.

2.
Rev. bras. cir. cardiovasc ; 36(1): 106-111, Jan.-Feb. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1155800

RESUMO

Abstract The importance of the vasa vasorum and blood supply to the wall of human saphenous vein (hSV) used for coronary artery bypass grafting (CABG) is briefly discussed. This is in the context of the possible physical link of the vasa vasorum connecting with the lumen of hSV and the anti-ischaemic impact of this microvessel network in the hSV used for CABG.


Assuntos
Humanos , Veia Safena , Vasa Vasorum , Ponte de Artéria Coronária , Veia Femoral
3.
Rev. bras. cir. cardiovasc ; 35(6): 964-969, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS, SES-SP | ID: biblio-1143982

RESUMO

Abstract Perivascular adipose tissue (PVAT) is a source of factors affecting vasomotor tone with the potential to play a role in the performance of saphenous vein (SV) bypass grafts. As these factors have been described as having constrictor or relaxant effects, they may be considered either beneficial or detrimental. The close proximity of PVAT to the adventitia provides an environment whereby adipose tissue-derived factors may affect the vasa vasorum, a microvascular network providing the vessel wall with oxygen and nutrients. Since medial ischaemia promotes aspects of graft occlusion the involvement of the PVAT/vasa vasorum axis in vein graft patency should be considered.


Assuntos
Veia Safena , Vasa Vasorum , Tecido Adiposo , Veia Femoral
4.
Rev. bras. cir. cardiovasc ; 35(5): 757-763, Sept.-Oct. 2020. tab, graf
Artigo em Inglês | LILACS, SES-SP | ID: biblio-1137320

RESUMO

Abstract It has been reported that severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection induces endothelial inflammation, therefore facilitating the progression of endothelial and vascular dysfunction in coronavirus disease 2019 (COVID-19) patients. Coronary artery bypass grafting (CABG) involves mainly the use of the saphenous vein (SV) and internal mammary artery as graft material in the stenosed coronary arteries. Unfortunately, graft patency of the SV is low due to endothelial dysfunction and inflammation. We propose that SARS-CoV-2 might cause vascular inflammation, endothelial dysfunction, and thrombosis in coronary artery bypass graft vessels by binding angiotensin-converting enzyme 2 receptor. Therefore, in this Special Article, we consider the potential influence of COVID-19 on the patency rates of coronary artery bypass graft vessels, mainly with reference to the SV. Moreover, we discuss the technique of SV graft harvesting and the therapeutic potential of focusing on endothelial dysfunction, vascular inflammation, and thrombosis for protecting coronary artery bypass grafts in COVID-19 infected CABG patients.


Assuntos
Humanos , Grau de Desobstrução Vascular , Ponte de Artéria Coronária , Infecções por Coronavirus/complicações , Oclusão de Enxerto Vascular/virologia , Veia Safena/cirurgia , Trombose/fisiopatologia , Endotélio Vascular/fisiopatologia , Resultado do Tratamento , Betacoronavirus , Inflamação/fisiopatologia
5.
Rev. bras. cir. cardiovasc ; 34(4): 480-483, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1020495

RESUMO

Abstract The saphenous vein (SV) is the most commonly used conduit for coronary artery bypass surgery (CABG) and the second conduit of choice in Brazil and many other countries. The radial artery (RA) is suggested, by some, to be superior to SV grafts, although its use in the USA declined over a 10 year period. The patency of SV grafts (SVG) is improved when the vein is harvested with minimal trauma using the no-touch (NT) technique. This improved performance is due to the preservation of the outer pedicle surrounding the SV and reduction in vascular damage that occurs when using conventional techniques (CT) of harvesting. While the patency of NT SVGs has been shown superior to the RA at 36 months in one study, data from the RADIAL trial suggests the RA to be the superior conduit. When additional data using NT SVG is included in this trial the difference in risk of graft occlusion between the RA and SV grafts dissipates with there no longer being a significant difference in patency between conduits. The importance of preserving SV structure and the impact of NT harvesting on conduit choice for CABG patients are discussed in this short review.


Assuntos
Humanos , Veia Safena/transplante , Doença da Artéria Coronariana/cirurgia , Ponte de Artéria Coronária/métodos , Artéria Radial/transplante , Grau de Desobstrução Vascular , Brasil , Metanálise como Assunto , Falha de Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA